Sofar Solar Inverter Models
Sofar Solar produces high-quality inverters for residential, commercial, and utility-scale solar installations. Sofar Solar inverters are known for their reliability, efficiency, and advanced monitoring capabilities. The product line includes HYD series (hybrid inverters with battery storage) and KTLX series (string inverters) with various power ratings. These diagnostic codes are applicable to the majority of Sofar Solar inverter systems. Error indicators typically manifest as error codes displayed on the inverter LCD screen, LED status lights, or in the monitoring portal. Error codes follow a three-digit numeric format (e.g., 002, 003, 005) with descriptive names (e.g., GridUVP, GridOFP, GFCI).
How to Read Error Codes
- • Check inverter LCD screen for error code display
- • Review LED status indicators on inverter
- • Check monitoring portal for system status messages
- • Note error code format (e.g., 002, 003, 005)
- • Consult Sofar Solar documentation for your specific model
- • Error codes are three-digit numbers with descriptive names
Sofar Solar Product Series
- • HYD Series - Hybrid inverters with battery storage
- • KTLX Series - String inverters for commercial use
- • Single-Phase Models - Residential applications
- • Three-Phase Models - Commercial and utility applications
- • Monitoring Systems - Advanced system monitoring and control
Understanding Diagnostic Codes
Sofar Solar inverter systems incorporate sophisticated diagnostic capabilities that automatically detect operational issues. When a problem is identified, the system communicates through error codes displayed on the inverter LCD screen, LED status indicators, and status messages in the monitoring portal. Error codes follow a three-digit numeric format (e.g., 002, 003, 005) with descriptive names (e.g., GridUVP, GridOFP, GFCI). This intelligent diagnostic framework enables rapid problem identification and helps determine the appropriate response. All Sofar Solar inverter series utilize continuous performance monitoring with real-time error detection. Error codes may vary slightly depending on firmware version and model. Always reference your specific model's installation manual for precise code definitions and consult with a certified Sofar Solar installer for professional diagnosis and repair.
Grid Voltage and Frequency Errors
Problems with AC grid voltage and frequency.
| Code | Meaning | Possible Causes | Solutions |
|---|---|---|---|
| 002 | GridUVP - Grid voltage too low |
|
|
| 009 | GridOVPInstant1 - Transient grid voltage overvoltage 1 |
|
|
| 010 | GridOVPInstant2 - Transient grid voltage overvoltage 2 |
|
|
| 014 | VGridUnbalance - Grid voltage unbalance |
|
|
Grid Frequency Errors
Problems with AC grid frequency.
| Code | Meaning | Possible Causes | Solutions |
|---|---|---|---|
| 003 | GridOFP - Grid frequency too high |
|
|
| 004 | GridUFP - Grid frequency too low |
|
|
Ground Fault and Leakage Current Errors
Problems with ground fault detection and leakage current.
| Code | Meaning | Possible Causes | Solutions |
|---|---|---|---|
| 005 | GFCI - Ground fault current interruption error |
|
|
| 021 | GFCIDeviceFault(DC) - Leakage current sampling error (DC) |
|
|
| 029 | ConsistentFault_GFCI - Leakage current consistency error |
|
|
Grid Protection and Islanding Errors
Problems with grid protection functions and islanding detection.
| Code | Meaning | Possible Causes | Solutions |
|---|---|---|---|
| 006 | OVRT fault - OVRT function fault |
|
|
| 007 | LVRT fault - LVRT function fault |
|
|
| 008 | IslandFault - Islanding protection fault |
|
|
| 011 | VGridLineFault - Grid voltage line fault |
|
|
| 013 | RefluxFault - Reflux protection fault |
|
|
Hardware Sampling and Measurement Errors
Problems with hardware sampling and measurement circuits.
| Code | Meaning | Possible Causes | Solutions |
|---|---|---|---|
| 017 | HwADFaultIGrid - Grid current sampling error |
|
|
| 018 | HwADFaultDCI - DC component of grid current sampling error |
|
|
| 019 | HwADFaultVGrid(DC) - Grid voltage sampling error (DC) |
|
|
| 020 | HwADFaultVGrid(AC) - Grid voltage sampling error (AC) |
|
|
| 022 | HwADErrDCI(AC) - DC component of grid current sampling error (AC) |
|
|
| 023 | HwADErrVGrid(DC) - Grid voltage sampling error (DC) |
|
|
| 024 | HwADErrVGrid(AC) - Grid voltage sampling error (AC) |
|
|
| 025 | HwADErrDCI(DC) - DCI sampling error (DC) |
|
|
| 026 | HwADErrIdcBranch - DC branch current sampling error |
|
|
PV System and Isolation Errors
Problems with PV system and isolation.
| Code | Meaning | Possible Causes | Solutions |
|---|---|---|---|
| 027 | PVLowImpedance - PV impedance to PE too low |
|
|
Communication and System Errors
Problems with internal communication and system functions.
| Code | Meaning | Possible Causes | Solutions |
|---|---|---|---|
| 030 | ConsistentFault_Vgrid - Grid voltage consistency error |
|
|
| 031 | ConsistentDCI - DCI consistency error |
|
|
| 033 | SpiCommFault(DC) - SPI communication error (DC) |
|
|
| 034 | SpiCommFault(AC) - SPI communication error (AC) |
|
|
| 035 | SChip_Fault - Chip fault (DC) |
|
|
| 036 | MChip_Fault - Chip fault (AC) |
|
|
| 037 | HwAuxPowerFault - Auxiliary power fault |
|
|
| 038 | InvSoftStartFail - Inverter soft start failed |
|
|
Arc Fault and PV System Errors
Problems with arc fault detection and PV system monitoring.
| Code | Meaning | Possible Causes | Solutions |
|---|---|---|---|
| 028 | PIDAbnormalOut - PID abnormal output |
|
|
| 039 | ArcShutdownAlarm - Arc protection shutdown alarm |
|
|
| 040 | LowLightChkFail - No detection of weak sunlight |
|
|
Critical Safety Notice
Do not attempt DIY repairs on your Sofar Solar system. The majority of diagnostic codes relate to high-voltage DC and AC electrical systems, grid connection safety mechanisms, or critical safety features. Specific codes requiring immediate professional intervention include: 005 (GFCI), 027 (PVLowImpedance), 039 (ArcShutdownAlarm), and other safety-related errors. Upon encountering these codes, immediately shut down the system if safe to do so and contact a certified Sofar Solar installer without delay.
Professional service is mandatory—contact a licensed solar installer or reach out to Sofar Solar technical support for expert assistance.
Maintenance Guidelines
Scheduled Service Requirements
- ✓Professional inspection and service annually by certified Sofar Solar installer
- ✓Monthly visual inspection of solar panels for damage or soiling
- ✓Clean panels quarterly or as needed based on local conditions
- ✓Monitor system performance daily through monitoring portal
- ✓Check inverter status and LCD screen monthly
- ✓For hybrid systems, monitor battery status and health
Proactive Maintenance Strategies
- ✓Keep panels clean to maximize energy production
- ✓Trim trees and vegetation to prevent shading
- ✓Inspect DC wiring and connections for damage or corrosion
- ✓Monitor production trends for early problem detection
- ✓Ensure adequate ventilation around inverter
- ✓Review system alerts and error codes promptly
- ✓Regularly check AC protection switch and wiring
Frequently Asked Questions
What does error code 002 (GridUVP) mean?
002 indicates grid voltage is too low. If the alarm occurs occasionally, the cause may be an abnormal state of the utility grid. The inverter will automatically return to normal operation when the grid state returns to normal. If the alarm occurs frequently, check if grid voltage/frequency is within the allowable range. If within range, check the AC protection switch and AC wiring of the inverter.
What should I do if I see error code 005 (GFCI)?
005 indicates a ground fault current interruption error. Check the inverter and wiring, inspect for ground faults, and test leakage current. Check GFCI device operation. If the error persists, contact your installer. Professional diagnosis is required.
What does error code 027 (PVLowImpedance) mean?
027 indicates PV impedance to PE (protective earth) is too low. This is a serious safety condition. Check PV isolation impedance, test PV system for ground faults, inspect PV module insulation, and check DC wiring for damage. If the error persists, contact your installer immediately. Professional diagnosis is required.
What should I do if I see error code 039 (ArcShutdownAlarm)?
039 indicates arc protection shutdown alarm. This is a critical safety condition. Do not attempt to restart. Check DC connections for arcs, inspect all DC connections for looseness, and check DC wiring for damage. Contact your installer immediately. Professional inspection is required before restart.
How do I check error codes on my Sofar Solar inverter?
Error codes can be viewed on the inverter LCD screen, through LED status indicators on the inverter, or in the monitoring portal. Check the LCD display for error messages (typically three-digit numbers like 002, 003, 005), observe the LED status lights, and log into your monitoring account to view system status and error history.
What does error code 003 (GridOFP) or 004 (GridUFP) mean?
003 indicates grid frequency is too high, and 004 indicates grid frequency is too low. If the alarm occurs occasionally, the cause may be an abnormal state of the utility grid. The inverter will automatically return to normal operation when the grid state returns to normal. If alarms occur frequently, check if grid voltage/frequency is within the allowable range.
Can I reset error codes by restarting the inverter?
Some error codes (like 002, 003, 004 for grid issues) may resolve automatically when grid conditions return to normal, but many codes indicate serious conditions that require professional diagnosis. Safety-related codes (GFCI, isolation faults, arc faults) should never be reset without professional inspection. Always follow the recommended solutions for each specific error code and contact a certified installer if the error persists.