Sol-Ark Error Codes

Expert reference guide covering all Sol-Ark inverter diagnostic codes with comprehensive troubleshooting procedures and professional repair guidance

Quickly identify problems with your Sol-Ark solar system and learn the correct response procedures

πŸ”§

Sol-Ark Inverter Models

Sol-Ark produces high-quality hybrid inverters for residential and commercial solar installations with integrated battery storage. Sol-Ark inverters are known for their advanced technology, efficiency, and intelligent energy management capabilities. The product line includes single-phase and three-phase hybrid inverters with various power ratings (5kW, 8kW, 12kW, 15kW, and higher). Sol-Ark inverters utilize Deye technology in their hardware and software. These diagnostic codes are applicable to the majority of Sol-Ark inverter systems. Error indicators typically manifest as error codes displayed on the inverter LCD screen, LED status lights, or in the monitoring portal. Error codes follow the format "F" followed by a two-digit number (e.g., F12, F13, F20).

How to Read Error Codes

  • β€’ Check inverter LCD screen for error code display
  • β€’ Review LED status indicators on inverter
  • β€’ Check Sol-Ark monitoring portal for system status messages
  • β€’ Note error code format (e.g., F12, F13, F20)
  • β€’ Consult Sol-Ark documentation for your specific model
  • β€’ Error codes typically start with "F" followed by numbers

Sol-Ark Product Series

  • β€’ Hybrid Inverters - Integrated battery storage solutions
  • β€’ 5kW, 8kW Models - Residential applications
  • β€’ 12kW, 15kW Models - Commercial applications
  • β€’ Energy Storage Systems - Complete battery solutions
  • β€’ Monitoring Systems - Advanced system monitoring and control
πŸ“‹

Understanding Diagnostic Codes

Sol-Ark inverter systems incorporate sophisticated diagnostic capabilities that automatically detect operational issues. When a problem is identified, the system communicates through error codes displayed on the inverter LCD screen, LED status indicators, and status messages in the Sol-Ark monitoring portal. Error codes typically follow the format "F" followed by a two-digit number (e.g., F12, F13, F20). Sol-Ark inverters utilize Deye technology, and some error codes may be similar to Deye inverter codes. This intelligent diagnostic framework enables rapid problem identification and helps determine the appropriate response. All Sol-Ark inverter series utilize continuous performance monitoring with real-time error detection. Error codes may vary slightly depending on firmware version and model. Always reference your specific model's installation manual for precise code definitions and consult with a certified Sol-Ark installer for professional diagnosis and repair.

DC Input and Polarity Errors

Problems with DC input connections and polarity.

CodeMeaningPossible CausesSolutions
F12DC Input Reverse Polarity - PV input polarity reversed
  • β€’Incorrect PV input polarity
  • β€’Positive and negative wires swapped
  • β€’Installation error
  • β€’DC connection mistake
  1. Check PV input polarity
  2. Verify positive and negative connections are correct
  3. Check wiring of solar modules
  4. Ensure connections are properly made
  5. Correct polarity if necessary
  6. Contact installer if unsure about connections

Isolation and Ground Fault Errors

Critical safety errors related to electrical isolation and ground fault detection.

CodeMeaningPossible CausesSolutions
F13DC Isolation Impedance Fault - Persistent DC isolation impedance error
  • β€’Inverter grounding problem
  • β€’Ground fault in PV system
  • β€’Isolation impedance below threshold
  • β€’Grounding cable issue
  • β€’DC isolation failure
  1. Check inverter grounding cable
  2. Verify proper grounding connection
  3. Test isolation impedance
  4. Check for ground faults in PV system
  5. Inspect DC wiring for damage
  6. Contact installer if error persists
  7. Professional diagnosis may be required
F14DC Leakage Current Fault - Unusual leakage current in DC circuit
  • β€’DC leakage current detected
  • β€’Insulation degradation
  • β€’Moisture in system
  • β€’Ground fault
  1. Check DC circuit for leakage
  2. Inspect insulation condition
  3. Check for moisture ingress
  4. If error persists, contact installer
  5. Professional diagnosis required
F15GFDI Ground Fault - Faulty connection of solar module to ground
  • β€’GFDI ground fault
  • β€’Faulty solar module grounding
  • β€’Ground connection issue
  • β€’GFDI circuit fault
  1. Check solar module connection
  2. Verify proper grounding
  3. Inspect GFDI circuit
  4. Check ground connections
  5. Contact installer if error persists
F20Isolation Fault - Ground fault in PV modules
  • β€’Ground fault in PV modules
  • β€’Isolation failure
  • β€’Module insulation problem
  • β€’DC ground fault
  1. Measure isolation of modules
  2. Disconnect DC switch if necessary
  3. Check PV module insulation
  4. Inspect DC wiring for ground faults
  5. Test isolation resistance
  6. Contact installer for professional diagnosis
  7. This is a serious safety condition

Memory and Storage Errors

Problems with internal memory and EEPROM storage.

CodeMeaningPossible CausesSolutions
F16Memory Read Error - Problem accessing internal memory (EEPROM)
  • β€’EEPROM read failure
  • β€’Memory corruption
  • β€’Internal memory error
  • β€’Storage access problem
  1. Restart the inverter
  2. If error persists, contact installer or Sol-Ark service
  3. May require firmware update
  4. Professional service may be needed
F17Memory Write Error - Problem writing to internal memory (EEPROM)
  • β€’EEPROM write failure
  • β€’Memory corruption
  • β€’Internal memory error
  • β€’Storage write problem
  1. Restart the inverter
  2. If error persists, contact installer or Sol-Ark service
  3. May require firmware update
  4. Professional service may be needed

Power Supply and Relay Errors

Problems with power supply and relay control.

CodeMeaningPossible CausesSolutions
F21Auxiliary Power Supply Failure - Missing DC 23V supply
  • β€’DC 23V power supply failure
  • β€’Auxiliary power circuit issue
  • β€’Internal power supply problem
  1. Restart the inverter
  2. Check power supply connections
  3. If error persists, contact installer or Sol-Ark service
  4. May require component replacement
F22AC Main Contactor Fault - Problem with AC main contactor
  • β€’AC main contactor failure
  • β€’Contactor control issue
  • β€’Component malfunction
  1. Check AC main contactor
  2. If error persists, contact installer
  3. Professional service required
F23AC Auxiliary Contactor Fault - Problem with AC auxiliary contactor
  • β€’AC auxiliary contactor failure
  • β€’Contactor control issue
  • β€’Component malfunction
  1. Check AC auxiliary contactor
  2. If error persists, contact installer
  3. Professional service required

Overcurrent and Current Measurement Errors

Problems with overcurrent protection and current measurement.

CodeMeaningPossible CausesSolutions
F24Phase Loss or AC Voltage Detection Failure - Loss of one phase or failure of part of AC voltage detection
  • β€’Phase loss
  • β€’AC voltage detection failure
  • β€’Three-phase imbalance
  • β€’AC connection issue
  1. Restart the inverter
  2. Check AC connections
  3. Verify all three phases are connected
  4. Check AC voltage on all phases
  5. If error persists, contact installer or Sol-Ark service
F25DC Firmware Overcurrent - Overcurrent in DC circuit
  • β€’DC overcurrent condition
  • β€’DC circuit overload
  • β€’Firmware detected overcurrent
  1. Check DC circuit for overload
  2. Verify DC current ratings
  3. If error persists, contact installer
  4. Professional diagnosis required
F26AC Firmware Overcurrent - Overcurrent in AC circuit
  • β€’AC overcurrent condition
  • β€’AC circuit overload
  • β€’Firmware detected overcurrent
  1. Restart the inverter
  2. Check AC circuit for overload
  3. Verify AC current ratings
  4. If error persists, contact installer or Sol-Ark service
  5. Professional diagnosis may be required
F28Three-Phase Current Overcurrent - Overcurrent in one of the phases
  • β€’Phase overcurrent
  • β€’Three-phase imbalance
  • β€’AC load issue
  1. Check three-phase current balance
  2. Verify AC load distribution
  3. If error persists, contact installer
F29Three-Phase Current Overcurrent - Overcurrent in one of the phases
  • β€’Phase overcurrent
  • β€’Three-phase imbalance
  • β€’AC load issue
  1. Restart the inverter
  2. Check three-phase current balance
  3. Verify AC load distribution
  4. If error persists, contact installer or Sol-Ark service

Leakage Current and GFCI Errors

Problems with leakage current detection and GFCI protection.

CodeMeaningPossible CausesSolutions
F27GFCI (RCD) AC Leakage Current Fault - Average leakage current over threshold
  • β€’AC leakage current too high
  • β€’GFCI/RCD fault
  • β€’Ground fault in AC circuit
  • β€’Leakage current exceeds threshold
  1. Check DC power supply and solar modules
  2. Restart the inverter
  3. Check for ground faults in AC circuit
  4. Test leakage current
  5. If error persists, contact installer or Sol-Ark service
  6. Professional diagnosis required

Hardware and Component Errors

Problems with internal hardware and component failures.

CodeMeaningPossible CausesSolutions
F30All Hardware Faults Synthesis - General hardware fault
  • β€’Multiple hardware faults
  • β€’General hardware failure
  • β€’Component malfunction
  • β€’Internal system error
  1. Contact installer immediately
  2. Export device log files for diagnosis
  3. This requires professional diagnosis
  4. Contact Sol-Ark support with log files
  5. May require component replacement or repair

Battery and Energy Storage Errors

Problems with battery connection and energy storage systems.

CodeMeaningPossible CausesSolutions
Battery Communication ErrorBattery Communication Failure - Communication lost with battery system
  • β€’Battery communication cable issue
  • β€’Battery BMS communication failure
  • β€’Communication protocol error
  • β€’Battery not responding
  1. Check battery communication cable connections
  2. Verify battery BMS is powered and responding
  3. Check communication protocol settings
  4. Restart inverter and battery system
  5. If error persists, contact installer or Sol-Ark service
Battery OvervoltageBattery Overvoltage - Battery voltage exceeds maximum limit
  • β€’Battery voltage too high
  • β€’Battery charging issue
  • β€’BMS fault
  • β€’Battery cell imbalance
  1. Check battery voltage
  2. Verify battery charging settings
  3. Check battery BMS status
  4. If error persists, contact installer
  5. Professional diagnosis required
Battery UndervoltageBattery Undervoltage - Battery voltage below minimum limit
  • β€’Battery voltage too low
  • β€’Battery discharged
  • β€’BMS fault
  • β€’Battery cell imbalance
  1. Check battery voltage
  2. Allow battery to charge if possible
  3. Check battery BMS status
  4. If error persists, contact installer
  5. Professional diagnosis required
⚠️

Critical Safety Notice

Do not attempt DIY repairs on your Sol-Ark solar system. The majority of diagnostic codes relate to high-voltage DC and AC electrical systems, grid connection safety mechanisms, or critical safety features. Specific codes requiring immediate professional intervention include: F20 (Isolation Fault), F13 (DC Isolation Impedance Fault), F15 (GFDI Ground Fault), F27 (GFCI Leakage Current Fault), and F30 (Hardware Faults). Upon encountering these codes, immediately shut down the system if safe to do so and contact a certified Sol-Ark installer without delay. For error code F30, export device log files before contacting support.

Professional service is mandatoryβ€”contact a licensed solar installer or reach out to Sol-Ark technical support for expert assistance.

πŸ”§

Maintenance Guidelines

Scheduled Service Requirements

  • βœ“Professional inspection and service annually by certified Sol-Ark installer
  • βœ“Monthly visual inspection of solar panels for damage or soiling
  • βœ“Clean panels quarterly or as needed based on local conditions
  • βœ“Monitor system performance daily through Sol-Ark monitoring portal
  • βœ“Check inverter status and LCD screen monthly
  • βœ“Monitor battery status and health for hybrid systems

Proactive Maintenance Strategies

  • βœ“Keep panels clean to maximize energy production
  • βœ“Trim trees and vegetation to prevent shading
  • βœ“Inspect DC wiring and connections for damage or corrosion
  • βœ“Monitor production trends for early problem detection
  • βœ“Ensure adequate ventilation around inverter
  • βœ“Review system alerts and error codes promptly
  • βœ“Regularly check battery communication connections
❓

Frequently Asked Questions

What does error code F12 (DC Input Reverse Polarity) mean?

F12 indicates that the PV input polarity is reversed. Check the PV input polarity, verify that positive and negative connections are correct, and check the wiring of solar modules. Ensure connections are properly made and correct polarity if necessary. Contact your installer if unsure about connections.

What should I do if I see error code F20 (Isolation Fault)?

F20 indicates a ground fault in PV modules. This is a serious safety condition. Measure the isolation of modules, disconnect the DC switch if necessary, check PV module insulation, and inspect DC wiring for ground faults. Test isolation resistance and contact your installer for professional diagnosis immediately.

What does error code F13 (DC Isolation Impedance Fault) mean?

F13 indicates a persistent DC isolation impedance error. Check the inverter grounding cable, verify proper grounding connection, test isolation impedance, and check for ground faults in the PV system. Inspect DC wiring for damage. Contact your installer if the error persists. Professional diagnosis may be required.

What should I do if I see error code F30 (All Hardware Faults)?

F30 indicates a general hardware fault. Contact your installer immediately, export device log files for diagnosis, and contact Sol-Ark support with the log files. This requires professional diagnosis and should not be attempted as a DIY repair. Component replacement or repair may be necessary.

How do I check error codes on my Sol-Ark inverter?

Error codes can be viewed on the inverter LCD screen, through LED status indicators on the inverter, or in the Sol-Ark monitoring portal. Check the LCD display for error messages (typically in F## format), observe the LED status lights, and log into your monitoring account to view system status and error history.

What does "Battery Communication Error" mean?

Battery Communication Error indicates that communication has been lost with the battery system. Check battery communication cable connections, verify the battery BMS is powered and responding, check communication protocol settings, and restart the inverter and battery system. If the error persists, contact your installer or Sol-Ark service.

Can I reset error codes by restarting the inverter?

Some error codes (like F16, F17, F21, F24, F26, F29) may be resolved by restarting the inverter, but many codes indicate serious conditions that require professional diagnosis. Safety-related codes (isolation faults, ground faults) should never be reset without professional inspection. Always follow the recommended solutions for each specific error code and contact a certified installer if the error persists.